Key result
The McCoy laryngoscope significantly reduced heart rate (p<0.0001) and systolic blood pressure (p<0.001) immediately after intubation compared to the Macintosh laryngoscope.
Why the study?
Laryngoscopy and intubation provoke a stress response and sympathetic stimulation, making attenuation of hemodynamic changes through modified instruments important for patient stability.
Does the McCoy laryngoscope reduce hemodynamic stress response compared to the Macintosh laryngoscope in patients undergoing elective surgery?
RCT (n=60)
Open-label
Chit method
No
Does the McCoy laryngoscope reduce hemodynamic stress response compared to the Macintosh laryngoscope in patients undergoing elective surgery?
p-value: p=<0.0001
The McCoy laryngoscope significantly attenuates the hemodynamic stress response during endotracheal intubation compared to the Macintosh laryngoscope.
McCoy may blunt intubation hemodynamics; leaves open whether it improves outcomes or warrants routine use.
Introduction: Laryngoscopy and intubation cause stress response and sympathetic stimulation within the body. Attenuation of these changes by pharmacological means and improved technique with modified instruments is of absolute importance, for stable hemodynamics of the patients. Aim: Comparison of stress response to laryngoscopy and intubation, Intubation Difficulty Score (IDS) using Macintosh and McCoy laryngoscopes. Material and methods: After obtaining institutional ethical committee approval and patient consent in this randomized study, sixty patients of ASA grade I and II, posted for elective surgery under general anaesthesia were intubated with Macintosh or McCoy laryngoscopes. Changes in heart rate, mean arterial pressure, systolic and diastolic blood pressure were observed upto 15 minutes after laryngoscopy, along with IDS. Results: McCoy group when compared with Macintosh group had significant reduction in heart rate at T0 (p value <0.0001), systolic blood pressure at T0, T1 and T15 (p value < 0.001), diastolic blood pressure at T0, T10 and T15 (p value <0.05), mean arterial blood pressure at T0, T10 and T15 (p value <0.05) was observed in this study. Conclusion: Hemodynamic stress response with McCoy blade laryngoscope was reduced in magnitude in comparison with Macintosh blade laryngoscope.
No takes yet. Share an insight, caveat, or question.
Thakkar et al. (2022) conducted an RCT in Elective surgery under general anaesthesia (n=60). McCoy laryngoscope vs. Macintosh laryngoscope was evaluated on Heart rate at T0 (immediately after intubation) (p=<0.0001). The McCoy laryngoscope significantly reduced heart rate (p<0.0001) and systolic blood pressure (p<0.001) immediately after intubation compared to the Macintosh laryngoscope.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: