This is the authors' abstract. We don't add key points for this paper.
In this study, an all-ceramic heat-flux sensor with high temperature resistance and no water-cooling system was designed to address the problems of short effective lifespan and low sensitivity of heat-flux sensors under harsh ultra-high temperatures and high heat-flux conditions. The sensor components comprised high temperature resistant ceramic materials, that is, alumina (Al2O3), indium tin oxide (ITO)-In2O3thermopile, and nano SiO2. Structural parameters of the proposed heat-flux sensor were optimized via simulations. A high-temperature test platform was built to evaluate the sensor performance; the sensor exhibited an excellent thermoelectric performance. The output voltage of the sensor reached 9.96 mV at 1300 °C, and the average sensitivity in the range of (50–340) kW/m2was 31.5 μV/(kW∙m-2). The drift rate of the proposed sensor in the high-temperature maintenance experiment at 1200 °C for 5 h was 2.7 (kW/m²)∙h-1. The time constant of the sensor under pneumatic heating was 2.3 s. The proposed sensor can continuously work at ultra-high temperatures; therefore, it can be practically employed in the heat flux measurement of turbines and supersonic aircrafts.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Dong et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: