Why the study?
Does transvenous lead extraction via the inferior approach using a gooseneck snare improve procedural success compared to simple manual traction in patients needing lead extraction?
Does transvenous lead extraction via the inferior approach using a gooseneck snare improve procedural success compared to simple manual traction in patients needing lead extraction?
Transvenous extraction of pacemaker leads via an inferior approach using a gooseneck snare is safe and effective, but stand-alone extraction of defibrillator leads using this approach is suboptimal.
Answers are grounded in this paper and cite their sources.
Inferior snare approach shows no success advantage over manual traction; leaves open targeted use in pacemaker leads pending randomized data.
BACKGROUND AND OBJECTIVES: The number of patients with cardiac implantable electronic devices needing lead extraction is increasing for various reasons, including infections, vascular obstruction, and lead failure. We report our experience with transvenous extraction of pacemaker and defibrillator leads via the inferior approach of using a gooseneck snare as a first-line therapy and compare extraction using a gooseneck snare with extraction using simple manual traction. SUBJECTS AND METHODS: The study included 23 consecutive patients (43 leads) who underwent transvenous lead extraction using a gooseneck snare (group A) and 10 consecutive patients (17 leads) who underwent lead extraction using simple manual traction (group B). Patient characteristics, indications, and outcomes were analyzed and compared between the groups. RESULTS: The dwelling time of the leads was longer in group A (median, 121) than in group B (median, 56; p=0.000). No differences were noted in the overall procedural success rate (69.6% vs. 70%), clinical procedural success rate (82.6% vs. 90%), and lead clinical success rate (86% vs. 94.1%) between the groups. The procedural success rates according to lead type were 89.2% and 100% for pacing leads and 66.7% and 83.3% for defibrillator leads in groups A and B, respectively. Major complications were noted in 3 (mortality in 1) patients in group A and 2 patients in group B. CONCLUSION: Transvenous extraction of pacemaker leads via an inferior approach using a gooseneck snare was both safe and effective. However, stand-alone transvenous extraction of defibrillator leads using the inferior approach was suboptimal.
No takes yet. Share an insight, caveat, or question.
Jo et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: