Theoretical analysis reveals invariant droplet size distributions in diffusion-controlled condensation systems, indicating universal scaling when the Gibbs-Thompson effect is negligible.
Nucleation and growth are studied in a system that undergoes diffusion-controlled condensation under gradual changes in parameters, such as cooling. It is demonstrated that when the Gibbs-Thompson effect becomes negligible, the system falls into a universal regime. i.e., the final droplet size distribution remains invariant under certain rescaling of system parameters. An approximate yet very accurate analytic form is obtained for the final droplet size distribution in this regime.
No takes yet. Share an insight, caveat, or question.
Alexei V. Tkachenko (2025) studied this question.