Experimental study demonstrates that pulsed blowing prevents inlet separation in short nacelles, indicating improved aerodynamic efficiency with reduced momentum.
Innovative short-inlet nacelle designs and disruptive technologies are essential for minimizing the drag and weight penalties of high-bypass-ratio turbofan engines. Active flow control (AFC) can mitigate inlet separation under off-design conditions by using local air injection at the inlet lip. This work investigates wind tunnel testing of continuous and pulsed blowing on a generic short-inlet UHBR nacelle at high angles of incidence (AoIs). The model is designed as a flow-through nacelle and is tested at a free stream Mach number of 0.15. The Reynolds number associated with the nacelle length is 2.4 × 10⁶ 2.4 × 10 6 . Static pressure tabs on the model surface and a traversable total pressure rake serve to evaluate the performance of AFC. Both continuous and pulsed blowing could prevent inlet separation for AoIs of 18∘ 18 ∘ and 22∘ 22 ∘ , reducing spatial total pressure non-uniformity by up to 80%. Here, the AFC performance showed strong sensitivity to the jet velocity. A comparison of required momentum revealed that pulsed blowing consumes 20% less momentum input than continuous blowing for the same improvement level. For an AoI of 26∘ 26 ∘ , only continuous blowing at maximum momentum input could effectively mitigate inlet separation. This experimental study confirms the potential of AFC to improve inlet flow under off-design conditions.