Key result
Navitor THV was associated with a higher 30-day rate of new permanent pacemaker implantation compared to Evolut PRO+.
Why the study?
Despite differing in design and hemodynamic performance, no direct comparative studies had evaluated difference rates in conduction disturbances between the self-expanding Evolut and Navitor transcatheter heart valves.
Does the Navitor transcatheter heart valve compared to the Evolut PRO+ valve affect the rate of new permanent pacemaker implantation in patients with severe aortic stenosis?
Cohort (n=880)
Yes
Does the Navitor transcatheter heart valve compared to the Evolut PRO+ valve affect the rate of new permanent pacemaker implantation in patients with severe aortic stenosis?
In patients undergoing TAVR for severe aortic stenosis, the Navitor valve was associated with a higher 30-day rate of new permanent pacemaker implantation but less moderate or greater paravalvular leak compared to the Evolut PRO+ valve.
Answers are grounded in this paper and cite their sources.
Navitor associated with higher pacemaker rates than Evolut; leaves open whether design differences drive conduction outcomes.
BACKGROUND: The Evolut and the Navitor transcatheter heart valves (THVs) represent the most widely used self-expanding implanted valves. Despite a similar implant concept, they markedly differ in design and hemodynamic performance. In both THVs, conduction disturbances following transcatheter aortic valve replacement (TAVR) are reported higher than in balloon-expandable devices. Nevertheless, to date, no direct comparative studies have analyzed their real difference rates. AIM: Aim of the present study was to directly compare the self-expanding Evolut PRO+ and Navitor THVs, with specific focus on the incidence of new permanent pacemaker implantation (PPI) and post-procedural hemodynamic performance. METHODS: The CONNAVIPRO registry is an international, multicenter, retrospective study including 880 consecutive patients with severe aortic stenosis treated with Evolut PRO+ (n = 451) or Navitor (n = 429) between May 2022 and December 2024. The primary endpoint was new PPI within 30 days among pacemaker-naïve patients. Secondary endpoints included technical and device success, transprosthetic gradients, and paravalvular leak (PVL). Inverse probability weighting (IPW) was applied to adjust for baseline differences. RESULTS: Procedural success was high with both valves (97.6%), and early safety outcomes were comparable. At 30 days, the Navitor group showed a higher PPI rate than Evolut (23.2% vs. 17.6%), reaching statistical significance after IPW adjustment (OR 1.53, 95% CI 1.08-2.17; p = 0.018). Mean transprosthetic gradients were slightly higher with Navitor (8 vs. 7 mmHg; p = 0.002), whereas moderate or greater PVL was less frequent (2.8% vs. 7.7%; p < 0.001). Variables independently associated with PPI were hypertension, and pre-existing right bundle branch block. CONCLUSIONS: Both Evolut PRO+ and Navitor THVs provided excellent safety and hemodynamic outcomes. Navitor may be associated with a higher 30-day PPI rate, a lower incidence of moderate or greater PVL, and clinically non-significant higher gradients. These associations should be interpreted as hypothesis-generating and warrant confirmation in prospective studies.
No takes yet. Share an insight, caveat, or question.
Poletti et al. (2026) conducted a cohort in Severe aortic stenosis (n=880). Navitor THV vs. Evolut PRO+ THV was evaluated on New permanent pacemaker implantation (PPI) within 30 days among pacemaker-naïve patients (OR 1.53, 95% CI 1.08-2.17, p=0.018). Navitor THV was associated with a higher 30-day rate of new permanent pacemaker implantation compared to Evolut PRO+.