Answers are grounded in this paper and cite their sources.
In the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the Berlin electron-storage ring BESSY II, a procedure has been developed to investigate the dependence of vacuum-ultraviolet reflection on polarization. It is based on characterizing the elliptically polarized synchrotron radiation at PTB's normal-incidence monochromator beamline for reflectometry by means of polarization-sensitive photodetectors. For this purpose, the polarization dependency in the detector responsivity was determined at a small, low, solid angle of acceptance for the synchrotron radiation, i.e., within the orbital plane of the storage ring where the degree of linear polarization is known to be almost 100%. Our method allows the polarization dependence of reflection samples to be measured with relative standard uncertainties ranging from 2.4% to 11% in the spectral range between 60 and 160 nm. The method has been applied to the optimization of polarizing mirrors at the Lyman-alpha wavelength of 121.6 nm.
No takes yet. Share an insight, caveat, or question.
Gottwald et al. (2007) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: