Answers are grounded in this paper and cite their sources.
Introduction Obstructive sleep apnea (OSA) is a highly prevalent chronic disorder that is challenging to monitor clinically. While single-night laboratory-based polysomnography (PSG) is the current gold standard for OSA assessment, its utility is limited by cost and inaccessibility. Overnight pulse oximetry is a feasible approach for simplified at-home monitoring of OSA. In this study, we evaluate the performance of a modified finger-worn pulse oximetry device (“Ring”) for OSA assessment. Methods In all, 25 patients with OSA [age: 55.5 ± 7.7 years (mean ± SD ), body mass index (BMI): 31.8 ± 5.1 kg/m 2 , 14M:11F, and Fitzpatrick scale score I–II: 15, III–IV: 6, and V–VI: 4] completed up to four in-laboratory PSG studies with simultaneous Ring oximetry measurements (90 studies in total). Correlation and agreement analyses compared Ring-derived measures of the oxygen desaturation index (ODI4 RING , desaturations ≥4%) against PSG measures (ODI4 PSG and AHI4 PSG ). Likewise, Ring-derived hypoxic burden (HB RING ) was compared against its PSG counterpart (HB PSG ). Receiver operator characteristic (ROC) curve analysis quantified the ability of ODI4 RING to identify moderate-to-severe OSA (AHI4 PSG > 15 events/h). Results Median [interquartile range (IQR)] of AHI4 PSG was 18.0 [9.6, 31.7] events/h. ODI4 RING was positively correlated with ODI4 PSG (Pearson r = 0.87, root mean square error [RMSE] = 6.6 events/h, intraclass correlation [ICC] = 0.85) and AHI4 PSG ( r = 0.85, RMSE = 7.1 events/h, ICC = 0.84). The bias (mean difference) and limits of agreement (1.96 SD ) between ODI4 PSG and ODI4 RING were 2.9 and 14.2 events/h, while for AHI4 PSG and ODI4 RING , the bias and limits of agreement were 1.4 and 16.3 events/h, respectively. HB RING was positively correlated with HB PSG ( r = 0.75, RMSE = 24.6% min/h, ICC = 0.73), with a mean difference of 3.7% min/h and limits of agreement of 60.6% min/h. The receiver operator characteristic curve analysis of ODI4 RING to identify moderate-to-severe OSA produced an area under the curve of 0.92 (ODI4 PSG > 15 events/h, “excellent”) and 0.84 (AHI4 PSG > 15 events/h, “excellent”). Conclusion Our results show that a low-cost, convenient, and simple-to-use finger-worn pulse oximeter is a reliable tool for continuous monitoring of OSA severity and therapy responses. It also offers excellent discriminative value for screening moderate-to-severe OSA in this population.
No takes yet. Share an insight, caveat, or question.
Gell et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: