Answers are grounded in this paper and cite their sources.
An innovative façade system in which the roof and side walls are transparent to solar radiation, with transparent insulating material parallel slats (TIM-PS) embedded between the glass façade and the solid wall, is proposed as a strategy to effectively reduce convective losses and intensify solar radiation penetration. This study proposes the validation of a model equipped with glass side walls and roof, using data provided by an experimental device. A numerical study was then carried out to investigate the effect of the TIM-PS included in the air duct and how the position of slats affects the performance of the proposed solution. The Optimal design is a T-T-W featuring with −45° TIM-PS. For the innovative T-T-W equipped with −45° TIM-PS heating duration has been extended by two hours. This original model allowed raising the thermal efficiency at 17H from 5% provided by the normal T-T-W up to 40%.HighlightsThermal performance is improved while retaining the simple geometric appearance of Trombe Wall.Where perpendicular TIM-PS system is included, thermal performance of T-T-W is 10 times higher than that of reference T-T-W.It has been proven that slats inclined at −45° provide the greatest effect in terms of optimizing the efficiency.In the case of −45° TIM-PS; efficiency increases up to 50% at 17H, while it is only 2% for the reference T-T-W, 20% for the perpendicular slats case and 23% for the case of −45° slats. The −45° provides the highest level of efficiency during the whole day.
No takes yet. Share an insight, caveat, or question.
Ammar et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: