Key result
Transseptal puncture at the fossa ovalis using electrocautery and a standard needle resulted in tissue coring in 35% of cases, compared to 0% without cautery (P<0.001).
Why the study?
Does the use of radiofrequency electrocautery with a standard transseptal needle increase the incidence of tissue coring compared to standard puncture without electrocautery in an excised swine heart model?
Does the use of radiofrequency electrocautery with a standard transseptal needle increase the incidence of tissue coring compared to standard puncture without electrocautery in an excised swine heart model?
Using radiofrequency electrocautery with a standard open-ended transseptal needle causes a high incidence of tissue coring, raising safety concerns for potential embolization.
Answers are grounded in this paper and cite their sources.
May raise embolization risk during transseptal access; leaves open human relevance from swine model.
BACKGROUND: The application of radiofrequency electrocautery to a standard, open-ended transseptal needle has been used to facilitate transseptal puncture (TSP). The purpose of this study was to determine the incidence of cardiac tissue coring when this technique is used. METHODS AND RESULTS: A model using excised swine hearts submerged in a saline-filled basin was developed to simulate TSP with electrocautery and a standard transseptal needle. Punctures were performed without the use of electrocautery and by delivering radiofrequency energy to the transseptal needle using a standard electrocautery pen at 3 target sites (fossa ovalis, non-fossa ovalis septum, and aorta). The tissue of the submerged heart was gently tented, and the needle was advanced on delivery of radiofrequency. The devices were retracted, and the needle was flushed in a collection basin. None of the TSPs without cautery caused tissue coring. For TSPs using electrocautery, the frequency of coring was at least 21% for any puncture permutation used in the study and averaged 37% at septal sites (P<0.001 compared with punctures without cautery). Tissue coring occurred in 33 of 96 (35%) punctures through the fossa ovalis and in 38 of 96 (40%) punctures through non-fossa ovalis septum. The frequency of tissue coring at aortic sites was 62 of 96 (65%), which was significantly higher than at the septal sites (P<0.001). CONCLUSIONS: In an animal preparation, TSP at the level of the fossa ovalis using electrocautery and a standard open-ended Brockenbrough needle resulted in coring of the septal tissue in 35% of cases (33 of 96 punctures).
No takes yet. Share an insight, caveat, or question.
Greenstein et al. (2012) studied Transseptal catheterization. Electrocautery with a standard transseptal needle vs. Standard transseptal needle without electrocautery was evaluated on Incidence of cardiac tissue coring (p=<0.001). Transseptal puncture at the fossa ovalis using electrocautery and a standard needle resulted in tissue coring in 35% of cases, compared to 0% without cautery (P<0.001).
Synapse has enriched 10 related papers. Consider them for comparative context: