This is the authors' abstract. We don't add key points for this paper.
A class of Actively Calibrated Line Mounted Capacitive Voltage Transducers (LMCVT) are introduced as a viable line mountable instrumentation option for deploying large numbers of voltage transducers onto the medium and high voltage systems. Active Calibration is shown to reduce the error of line mounted voltage measurements by an order of magnitude from previously published techniques. The instrument physics and sensing method is presented and the performance is evaluated in a laboratory setting. Finally, a roadmap to a fully deployable prototype is shown.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Sevlian et al. (2017) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: