The aim of this study is to evaluate the effects of materials used in bar construction in all-on-four (AOF) and all-on-three (AOT) concepts on stress transmission by three-dimensional (3D) finite element analysis (FEA) method. Materials and methods: Two models were designed to simulate the AOF and AOT concepts in the mandible. For the AOF concept, the mesial implants were placed at the canine teeth position and the distal implants were inclined 40 distally, with the neck portions protruding from the second premolar region on both sides. For the AOT concept, one of the implants was placed in the middle of the two incisors in the mandible and the other two implants were placed distally in the first premolar region. Bars and prostheses were designed and the model parts were combined. Four different bar materials were defined after creating four different models for both concepts. A force of 100 N was applied perpendicular to the long axis of the left first molar tooth from the central fossa. Elastic strain values of bar structures and bone tissue were obtained.