This is the authors' abstract. We don't add key points for this paper.
A gyrotron and a matching optics unit (MOU) for the multi-frequency electron cyclotron heating and current drive (ECH/CD) system in JT-60SA have been developed successfully. The gyrotron demonstrated stable operation at high powers of 1.5 MW for 5 s and 1.9 MW for 1 s at 110 GHz. To obtain high HE 11 mode purity (>90%) at the outlet of the waveguide in the ECH/CD launcher, a MOU for operating at three frequencies of 82 GHz, 110 GHz, and 138 GHz that includes three pairs of water-cooled phase correcting mirrors has been developed, which allows the mirrors to be changed without opening the evacuated MOU. The mode purity at the inlet of a dummy load in the transmission line was evaluated at high-power and an HE 11 mode purity of >90% was obtained at three frequencies.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Kobayashi et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: