Answers are grounded in this paper and cite their sources.
High renewable penetration is reshaping the operation of distribution networks by increasing the variability, uncertainty, and spatial dispersion of power injections. In particular, photovoltaic (PV) generation introduces rapid voltage fluctuations, while electric vehicles (EVs) create flexible but highly time-varying demand. These changes fundamentally challenge conventional voltage regulation mechanisms in modern distribution systems. In modern smart grids, the integration of distributed energy resources (DERs), such as PV systems and EVs, has introduced new challenges in voltage regulation and power quality. As the penetration of inverter-based resources increases, maintaining voltage stability becomes more complex due to the variability and dynamic behavior of these resources. Traditional voltage–var control (VVC) methods, including centralized optimization, local droop control, and distributed schemes, are often insufficient to address the fast-evolving and decentralized nature of such systems. This paper proposes a two-stage coordinated VVC framework that integrates centralized day-ahead optimization with physics-informed AI-based local controllers for EV inverters in active distribution networks. Unlike conventional droop-based methods that rely on predefined low-dimensional control curves and centralized optimization approaches that require intensive communication and computation, the proposed framework enables fast local voltage regulation while preserving grid-level coordination. In Stage I, an AC branch-flow-based optimization coordinates OLTCs, capacitor banks, and PV/EV inverter set-points to obtain voltage-secure operating schedules. In Stage II, a residual multi-layer perceptron controller embedded in each EV inverter learns nonlinear reactive power correction policies from OPF-based solutions using only local measurements and scheduling information. Instead of conventional low-dimensional droop curves (Q(V), Q(P)), each EV inverter implements a residual multi-layer perceptron that maps rich local feature vectors—including voltage, active power, state-of-charge, tariff signals, and day-ahead set-points—to reactive power corrections. The network output is parameterized to satisfy inverter apparent-power limits by construction. The controller is trained offline using optimal set-points obtained from day-ahead or real-time optimal power flow, augmented with a physics-informed voltage penalty derived from the power-flow equations and admissible voltage bounds.
No takes yet. Share an insight, caveat, or question.
Zhong et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: