Why the study?
Mitral and tricuspid valve pulsed Doppler velocities and derived gradients are commonly evaluated, but data on normal pediatric values are limited.
What are the normal values and physiological variability of mitral and tricuspid inflow pulsed Doppler parameters in healthy children?
What are the normal values and physiological variability of mitral and tricuspid inflow pulsed Doppler parameters in healthy children?
This study establishes normal reference values and describes the physiological variability of mitral and tricuspid inflow pulsed Doppler parameters across different age groups in healthy children.
Answers are grounded in this paper and cite their sources.
Provides pediatric MV/TV Doppler reference ranges; extends limited normative data for echocardiographic interpretation in children.
Background: While mitral (MV) and tricuspid valve (TV) pulsed Doppler velocities and derived gradients are commonly evaluated, data on normal pediatric values are limited. This study aimed to evaluate the normal values and physiological variability for MV and TV Doppler velocities and derived gradients in a large cohort of prospectively enrolled healthy children. Methods: The echocardiographic measurements included pulsed Doppler MV and TV E and A velocities, E deceleration times (EDT), maximal and mean gradients, and velocity time integral (VTI). Results: A total of 544 healthy subjects (median age 6.4 years, range 1 day–17.68 years) were included. MV and TV E velocity, E/A ratio, and E and A wave duration increased, while A velocity decreased with age (p < 0.001). Along with an increase in VTI, there occurred a progressive increase in maximum velocity and gradients and a decrease in mean velocities and gradients. E/A inversions were common, especially at the TV in neonates and infants. For MV, inversion in either one, two, or three consecutive beats occurred in 51.9% of neonates and 18.3% of infants, while it was rare at older ages (all p < 0.001). For TV, inversions in three consecutive beats occurred in 71.4% of neonates, while inversions in only one or two beats were more common in infants (27.3%). For TV, inversion in one or more beats, however, was not infrequent at all ages. Conclusions: We report normal values and patterns of normality and physiological variability for MV and TV inflow Doppler from a large population of healthy children.
No takes yet. Share an insight, caveat, or question.
Cantinotti et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: