Why the study?
With clinical trials of treatments ongoing for cardiac transthyretin amyloidosis, quantitative nuclear scintigraphy is anticipated to evaluate efficacy, prompting investigation into its utility for monitoring disease load changes over time.
Does serial 99mTc-DPD scintigraphy reliably monitor changes in disease load in patients with cardiac transthyretin amyloidosis?
Does serial 99mTc-DPD scintigraphy reliably monitor changes in disease load in patients with cardiac transthyretin amyloidosis?
Serial 99mTc-DPD scintigraphy shows high variance in quantifying cardiac transthyretin amyloidosis disease load, suggesting caution when using it to monitor individual patients over short periods.
Serial 99mTc-DPD scintigraphy may inadequately track individual ATTR-CM progression; leaves open need for validated quantitative endpoints in trials.
Purpose Cardiac transthyretin amyloidosis is a usually fatal form of restrictive cardiomyopathy for which clinical trials of treatments are ongoing. It is anticipated that quantitative nuclear medicine scintigraphy, which is experiencing growing interest, will soon be used to evaluate treatment efficacy. We investigated its utility for monitoring changes in disease load over a significant time period.Methods Sixty-two treatment-naive patients underwent 99mTc-labelled 3,3-diphosphono-1,2propanodicarboxylic acid (99mTc-DPD) scintigraphy two to four times each over a five-year period. Quantitation of cardiac 99mTc-DPD retention was performed according to two established methods: measurement of heart-to-contralateral ratio (H/CL) in the anterior view (planar) and percentage of administered activity in the myocardium (SPECT).Results In total 170 datasets were analysed. Increased myocardial retention of 99mTc-DPD was demonstrable as early as 12 months from baseline. Year-on-year progression across the cohort was observed using SPECT-based quantitation, though on 30 occasions (27.8%) the change in our estimate was negative.Conclusions The spread of our results was notably high compared to the year-on-year increases. If left unaccounted for, variance may draw fallacious conclusions about changes in disease load. We therefore urge caution in drawing conclusions solely from nuclear medicine scintigraphy on a patient-by-patient basis, particularly across a short time period.
No takes yet. Share an insight, caveat, or question.
Ross et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: