Answers are grounded in this paper and cite their sources.
In this work, we present a discriminative optical fiber sensor for temperature and strain measurement. The sensor comprises of two cascaded thermal regenerated Fiber Bragg gratings (RFBGs) incorporated with two fused silica capillary tubes. The RFBG2is loosely enclosed in a fine fused silica tube and made solely sensitivity to temperature whereas the RFBG1sensor still retains its sensitivity to both strain and temperature. These properties have made the discriminative measurement accurate and directive. The experimental results indicate that temperature response is linear in the range of 100 – 1000°C with the sensitivity of ~15.7 pm/°C. Besides, it presents good repeatability in strain detection at high temperatures (300 °C – 900 °C). The incorporation of the two fine glass tubes has enhanced the modified RFBG’s strain sensitivity to as high as ~5.46 pm/μ εin the measurement range of0~μ εto 120μ εat 600 °C, which is about five times higher than that of common RFBG strain sensors. The sensitivity can be further enhanced by manipulating the parameters of the sensor’s structure.
No takes yet. Share an insight, caveat, or question.
Tian et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: