Answers are grounded in this paper and cite their sources.
The study of the asymmetry of the light diffracted by ultrasonic waves progressing with moderate amplitudes in liquids is used to detect and measure the finite amplitude distortion in water and carbon tetrachloride. A theory is developed which relates the distortion present to available isothermal compressibility measurements. This development includes the presence of absorption. Measurements of the second harmonic were made in water at 2 Mc and 4 Mc, at distances up to 50 cm, and at peak ultrasonic pressures between zero and 1.5 atmos. More detailed measurements were made in carbon tetrachloride at frequencies of 2 and 3 Mc, at distances up to 21 cm, and at pressures up to 0.7 atmos. For both liquids, good agreement is obtained between the experimentally measured values and the theoretically predicted results. Small amounts of distortion were easily measured. The second harmonic could be measured when the intensity of the harmonic was less than 0.04% of the intensity of the fundamental. Distortion could be measured when the fundamental was much less than 0.2 atmos.
No takes yet. Share an insight, caveat, or question.
Zankel et al. (1959) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: