An absolute capacitance measuring device based on the fundamental charge, capacitance and voltage relationship is described. It consists of a pair of CMOS analogue switches and a current integration amplifier, resulting in a simple capacitance transducer capable of providing a programmable measurement frequency ranging from 100 kHz to 5 MHz. This makes the transducer suitable for component concentration measurement of multicomponent flow processes involving conductive fluids. The initial circuit design is followed by a mathematical model of the transducer. Parametric analysis of this model is used to optimise both the sensitivity and stability of the transducer. A discrimination of 0.01 pF in 10 pF full scale is achieved. In measurements of capacitance with one plate grounded, the problem of stray capacitance arises. A novel switched guard method has been devised which reduces the effect of strays by a factor of 0.0025 at an operating frequency of 1 MHz.