Answers are grounded in this paper and cite their sources.
The rates of pipe breakage with increasing pipe diameter and times are investigated. Failure rates for cast-iron pipe are found to decrease with increasing diameter. Changes in pipe failure rates for the various modes of failures are examined in detail. Asbestos-cement and cast-iron pipe overall failure rates are found to increase with time, but for different reasons. Analysis of the modes of failure shows that joint failure is predominant for cast-iron pipe systems with bolted and universal joints whereas the predominant mode of failure for asbestos-cement pipe systems is circumferential cracking.
No takes yet. Share an insight, caveat, or question.
Kettler et al. (1985) studied this question.