Answers are grounded in this paper and cite their sources.
Twenty-one mature New Zealand white female rabbits were allocated into three groups of seven rabbits. Group I received a bolus of doughy Simplex polymethylmethacrylate (PMMA) cement injected into the proximal tibia through a drill hole. Group II received a preformed, cooled, bulk PMMA pellet. Group III had particulate PMMA powder implanted. The operated, but nonimplanted, left tibiae served as controls. Animals were killed after four months. Histologically, both Group I and Group II demonstrated a thin, fibrous tissue membrane at the implant interface. Particulate PMMA (Group III) stimulated a much thicker, florid, foreign body reaction composed of histiocytes and giant cells. The foreign body response to particulate acrylic cement was similar to that seen in failed cemented joint replacement arthroplasty in humans.
No takes yet. Share an insight, caveat, or question.
Goodman et al. (1988) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: