The procedure of reversing the polarity of the voltage applied to an ionization chamber and taking the average of the readings at each polarity has been mentioned by many workers. This is done to eliminate errors caused by stray currents which are independent of the chamber voltage. The difference in readings is usually reported to be small (about 1 per cent) but can be significant in electron build-up measurements. Howarth et al. (2) recently reported an appreciable difference. As a typical case, they found the measured relative surface ionization to be 0.30 or 0.36, depending upon the polarity of the voltage used. During the course of electron build-up studies made in this laboratory, even greater differences were found. Because of the uncertainty this gave to the accuracy of the measurements, a careful investigation was made. The Air Volume Ionization Chamber The ionization chamber used for electron build-up measurements in a cobalt 60 beam followed the design of Trump and Cloud (5) and of Miller (3), with a few modifications. Although similar to other instruments, its construction is shown in order that the characteristic which causes the reverse polarity effect observed may be more dearly described. The chamber (Fig. 1) was constructed of Lucite with a 0.5-mm. sheath of Teflon surrounding the current collecting system so as to minimize leakage currents. A 0.03-mm. sheet of Polystyrene, the window, was mounted over the body of the chamber leaving a 1.0-mm. air gap between the two. The under surface of the window was coated with Aquadag and served as one electrode. Both the top and bottom of the Lucite body were given an Aquadag coating, and a very narrow groove, not shown, was cut in the top to define the 2-cm. diameter active volume. The remainder of the top served as a guard ring, and the bottom served as an electrical shield. The ionization chamber was imbedded in the surface of a one cubic foot Masonite phantom. The current was measured by means of a vacuum tube electrometer bridge circuit designed by T. E. Bortner (1), Oak Ridge National Laboratory. The lead box containing the electrometer tube and a 1010-ohm resistance was connected to the chamber by an aluminum wire passing through a Ceresin-filled aluminum tube 15 cm. in length. The guard ring was at ground potential, the current collector was grounded through the 1010-ohm resistance and a potentiometer in series, and the high voltage was applied to the window. A null method was used to measure the current in which the voltage across the 1010-ohm resistance was balanced by an equal and opposite voltage from the potentiometer. Effect of Chamber Voltage The distribution of ionization in the first few millimeters of tissue-like material was determined using Lucite and Polystyrene absorbers (4).
No takes yet. Share an insight, caveat, or question.
Jasper E. Richardson (1954) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: