This is the authors' abstract. We don't add key points for this paper.
Deep learning models have shown great potential in reducing low-dose (LD) positron emission tomography (PET) image noise by estimating full-dose (FD) images from the corresponding LD images. Those models, however, when trained on paired LD-FD PET images from a source scanner, fail to generalize well when applied to LD PET images from a target scanner, due to a phenomenon called “domain drift.” In this study, we present a method for cross-scanner LD PET image noise reduction. This is done via a self-ensembling framework using a limited number of paired LD-FD PET images and a large number of LD PET images from the target scanner. The self-ensembling framework leverages the paired 2-D slices from both scanners to learn a regression model. It additionally incorporates a consistency loss on the LD PET images from the target scanner to enhance the model’s generalization capability. We conduct experiments on three datasets, respectively, acquired from three different scanners, including a GE Discovery MI (DMI) scanner, a Siemens Biograph Vision 450 (Vision) scanner, and a UI uMI 780 (uMI) scanner. Results from our comprehensive experiments demonstrate the generalization capability of our method.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: