Answers are grounded in this paper and cite their sources.
A calorimeter equipped with a thermister capable of measuring the temperature change down to 0.5 ×10−4°C was constructed. By this apparatus the heats of dilution of three polystyrene solutions were measured and the values of interaction parameters were derived. The μ values for toluene solution and chloroform solution were both negative and large, but that for ethylbenzene solution was zero. In order to compare with the polymer solution, the heat of mixing of ethylbenzene, which may be regarded as the monomer-unit of polystyrene, with same solvents were also measured and it was found that the interaction parameters of polymer solutions have the same signs as that of the corresponding monomer-unit solutions.
No takes yet. Share an insight, caveat, or question.
Amaya et al. (1956) studied this question.