Key result
Electrocardiographic features including peak deflection index, V2 R wave duration, V2 transition ratio, and pacemapping score independently predicted failed RVOT ablation of idiopathic OT-VAs.
Why the study?
What electrocardiographic features predict failed or recurrent right ventricular outflow tract catheter ablation in patients with idiopathic ventricular arrhythmias?
Cohort (n=264)
What electrocardiographic features predict failed or recurrent right ventricular outflow tract catheter ablation in patients with idiopathic ventricular arrhythmias?
Specific ECG features (PDI, V2Rd, V2 transition ratio) and pacemapping scores can predict failed RVOT ablation, while earliest activation time predicts recurrence in idiopathic ventricular arrhythmias.
May aid pre-procedural risk stratification for failed RVOT ablation; hypothesis-generating and requires prospective validation.
Introduction Various ECG algorithms have been proposed to identify the origin of idiopathic outflow tract (OT)‐ventricular arrhythmia (VA). However, electrocardiographic features of failed and recurrent right ventricular outflow tract (RVOT) ablation of idiopathic OT‐VAs have not been clearly elucidated. Methods and results A total of 264 consecutive patients (mean age: 44.0 ± 13.0 years, 96 male) undergoing RVOT ablation for OT‐VAs with a transition ≥V 3 , including 241 patients (91.6%) with initially successful procedures and 23 patients (8.4%) with failed ablation. Detailed clinical characteristics and ECG features were analyzed and compared between the two groups. VAs with failed RVOT ablation had larger peak deflection index (PDI), longer V 2 R wave duration (V 2 Rd), smaller V 2 S wave amplitude, higher R/S ratio in V 2 , higher V 3 R wave amplitude, and larger V 2 transition ratio than those with successful ablation. Multivariate analysis demonstrated that PDI, V 2 Rd, V 2 transition ratio, and pacemapping score acquired during mapping independently predicted failed ablation (P = 0.01, P = 0.01, P = 0.01, and P < 0.001, respectively). In 31 recurrent cases (12.8%) after initially successful ablation, multivariate Cox regression analysis showed that only the earliest activation time acquired during mapping predicted the recurrences after successful ablation (P = 0.001). The recurrent cases displayed different ECG features comparing with those with failed ablation. Conclusion The electrocardiographic features of failed RVOT ablation of idiopathic OT‐VAs with a transition ≥V 3 were characterized by PDI, V 2 Rd, V 2 transition ratio, and pacemapping score acquired during mapping, unlike the recurrent RVOT ablation.
No takes yet. Share an insight, caveat, or question.
Yamada et al. (2017) conducted a cohort in Idiopathic outflow tract-ventricular arrhythmia (n=264). Electrocardiographic features (peak deflection index, V2 R wave duration, V2 transition ratio, pacemapping score) was evaluated on Failed RVOT ablation (p=<0.001). Electrocardiographic features including peak deflection index, V2 R wave duration, V2 transition ratio, and pacemapping score independently predicted failed RVOT ablation of idiopathic OT-VAs.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: