A rocksalt, vacuum, double monochromator is described that displays the entire spectrum out to 15μ (or selected portions thereof at higher resolution) in one minute on a long-persistence oscilloscope screen. It measures percent transmission directly, automatically correcting for source-intensity distribution and spectrometer losses. Special arrangements permit rapid preparation of samples for analysis. Reflection measurements and direct comparison of two emission sources can also be made.
No takes yet. Share an insight, caveat, or question.
Baker et al. (1943) studied this question.