Answers are grounded in this paper and cite their sources.
OBJECTIVE: The 2023 European Society for Vascular Surgery (ESVS) guidelines on radiation safety recommended establishment of national diagnostic reference levels (DRLs) for endovascular procedures, which indicate an expected radiation dose for any given procedure for the average sized patient. The aim of this study was to propose a national DRL for Sweden for standard endovascular aortic repair (EVAR). METHODS: This was a national registry based study where all EVARs performed in Sweden over a two year period (2021 - 2022) were identified in the Swedish vascular registry, Swedvasc. Patient demographics were extracted from Swedvasc and radiation related parameters were collected at centre level. Multivariable analyses were performed to assess which factors affected fluoroscopy time, total dose area product (DAP), and cumulative air kerma (CAK). The national DRL was defined as the third quartile of all centre specific median values for DAP total. RESULTS: for intact and ruptured EVARs, respectively. In a multivariable linear regression analysis, rupture, iliac branched repair, access complication, obesity, low centre volume and larger aneurysm were predictors for higher DAP during EVAR. CONCLUSION: for EVAR procedures in Sweden, with specific benchmark DAP values proposed for subgroups of patients. There is a considerable difference in radiation dose between different centres, suggesting a potential for implementation of improved radiation routines in some centres based on benchmarking.
No takes yet. Share an insight, caveat, or question.
Markusdottir et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: