Why the study?
Do myocardial deformation parameters on 3D speckle tracking echocardiography correlate with exercise capacity on cardiopulmonary exercise testing in patients with heart failure?
Do myocardial deformation parameters on 3D speckle tracking echocardiography correlate with exercise capacity on cardiopulmonary exercise testing in patients with heart failure?
Answers are grounded in this paper and cite their sources.
Left ventricular early diastolic function, specifically the 25%Untwist value on 3D speckle tracking echocardiography, is a modest independent predictor of aerobic exercise capacity in heart failure patients.
Purpose Heart failure ( HF ) is a multifactorial entity that combines derangements in both systolic and diastolic function. The relationship between systolic and diastolic function and exercise capacity is not fully understood. We sought to determine the mechanisms linking cardiac function and exercise tolerance in patients with HF . Methods One hundred fifty‐six subjects with different cardiac function levels were included in the study. Subjects’ 2D echocardiographic, 3D speckle tracking echocardiographic, and cardiopulmonary exercise testing ( CPET ) data were collected. Result The amount of untwisting at 25% of the untwist duration (25%Untwist) and global longitudinal peak systolic strain ( GLS ) showed the best positive correlations with peak oxygen uptake (peak VO 2 ) ( r = .41; P < .001 and r = .32; P < .001, respectively), while the left ventricular ejection fraction ( EF ) was weakly correlated with peak VO 2 . The 25%Untwist value was negatively correlated with the carbon dioxide equivalent slope ( VE / VCO 2 ) ( r = −.49; P < .001). Both E / e and the left atrium volume index ( LA index) exhibited good positive correlations with VE / VCO 2 ( r = .39; P < .01 and r = .32; P < .001). In the multiple regression analysis, the best predictive model for the peak VO 2 included the 25%Untwist, GLS , and E / e , explained 64% of the variation in peak VO 2 , with 25%Untwist explaining 17.6% of the variation. Including EF in the model explained only 3.1% of the variation in peak VO 2 . In a multivariable model for VE / VCO 2 , 25%Untwist was the strongest independent predictor, explaining 23% of the variance in VE / VCO 2 . Conclusion Left ventricular early diastolic function is a modest independent predictor of aerobic exercise capacity. The 25%Untwist value is a good indicator of cardiac diastolic function.
No takes yet. Share an insight, caveat, or question.
Li et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: