This paper presents a very robust 6x OSR receiver for 0.2–2 Gb/s binary NRZ signals, introducing an adaptive equalizer that is auto-calibrating on sample data statistics for reliable data recovery in presence of excessive intersymbol interference, noise and crosstalk. The proposed time domain analysis of the data eye obtained with the oversampling architecture is used to tune the equalizer transfer characteristic. The auto-calibration scheme is fully implemented in the digital domain, resulting in a hardware and power efficient architecture with low process-voltage-temperature (PVT) sensitivity. This robust and highly digitized receiver is demonstrated in 0.18μmCMOS technology and is able to equalize variable cable losses up to 22 dB @ 1 GHz. The self-adaptive equalizer solution occupies only 0.05mm²and consumes 9 mW from a 1.8 V supply and can handle up to 20 m 100-ΩSTP cable @ 2 Gb/s. The entire receiver consumes 110 mW operating at 2 Gb/s with bit error rates of better than≪ 10⁻¹².
No takes yet. Share an insight, caveat, or question.
Gerfers et al. (2008) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: