Answers are grounded in this paper and cite their sources.
MS/MS spectra generated in ion-trap instruments are often very simple due to the low energy characteristic of the resonant excitation used for collision-induced dissociation (CID).1 For excitation, multiple-frequency resonant excitation techniques such as ‘tailored waveform’ (TWF), ‘stored waveform inverse Fourier transform’ (SWIFT) or ‘filtered noise fields’ (FNF) are used.1 FNF uses a single excitation waveform containing all frequencies to excite all of the ions in the trap (noise field).2, 3 Digital filtering is applied before the waveform is converted to an analog signal in order to filter-out selected secular frequency components corresponding to a single mass, multiple masses or mass bands (‘notches’). The resulting FNF signal removes all of the other ions from the trap. FNF can be used as an excitation method for MS/MS by masking all frequencies except for a window centered at the frequency of motion for the precursor ion. Linked MS n experiments can be achieved by applying multiple reverse-notch excitation bands corresponding to the FNF tickle frequencies for the precursor ion(s) and anticipated product ions at the same time. The latter technique was used in this study to simplify multiple CID experiments. The linked MS n approach is interesting for certain compound classes which do not exhibit meaningful fragmentation patterns in low-energy CID on triple-quadrupole and ion-trap instruments and thus show only simple product ion spectra with only structure-unspecific ions.4, 5 To overcome these limitations, sequential MS n experiments are usually performed on ion-trap instruments. These sequential procedures, however, cannot always be readily combined with fast chromatography or electrophoresis separations, because the long microscan times in sequential MS n may be too slow to get enough data points across the narrow chromatography peaks. In this study, MS n in one rapid scan-cycle using linked FNF sequences was applied to obtain structure-diagnostic fragment ions for a series of 7-(N′-alkylpiperazinyl)-6-fluoroquinolones (Fig. 1), a group of chemical veterinary and clinical antibiotics.4, 5 7-(N′-Alkylpiperazinyl)-6-fluoroquinolone antibiotics investigated. The experimental setup used was a high performance liquid chromatography (HPLC) system from Merck (Model L-7100, Darmstadt, Germany) in combination with Purospher Star columns (2.0 × 50mm, 3µm particles, Merck), operated at flow-rates of 0.3 mL/min. Separations were accomplished using acetonitrile/water (+0.1% formic acid) gradients. The analytes were extracted from urine samples by on-line preconcentration on a short column packed with a restricted access material (RAM; Merck ADS C-18, 20 × 2mm). During these extractions, 100 µL of the urine samples were enriched on the ADS column at a flow-rate of 1 mL/min using a secondary HPLC pump (mobile phase: 98% water/2% acetonitrile). The elution of the enriched antibiotics and the transfer to the analytical column were achieved with the mobile-phase gradient program. Electrospray data were acquired using a Merck-Hitachi M-8000 LC/3DQ ion-trap mass spectrometer in positive ion mode. The instrument was operated at a spray voltage of 3.5 kV, a drift voltage of 50 V and a focus voltage of 35 V. Various MS n experiments were performed using different FNF techniques. In MS/MS, the choice of diverse product ions for confirmation purposes is often not possible because low-energy CID does not lead to the formation of the desired ions. One of the chemical classes where only simple MS/MS spectra are observed are the 7-(N′-alkylpiperazinyl)-6-fluoroquinolones (Fig. 1). Previously, Schilling et al.4 and Volmer and Locke5 used three transitions in the triple-quadrupole MRM analyses of these substances, one corresponding to reaction in the piperazine group ([MH − CO2 − C2H5N]+) and two involving the carboxyl function ([MH − H2O]+ and [MH − CO2]+, respectively), to monitor these compounds in biological and environmental samples. No other intense ions were formed upon CID. While the 7-(N4′-alkylpiperazinyl) group and the corresponding ion formed under CID are certainly highly diagnostic and specific for certain quinolones, losses of water and CO2 from the protonated molecules are very common and may not be regarded as sufficiently specific for confirmation. Ideally, product ions reflecting the substituting groups at N-1, C-6, C-7 and C-8 are needed. In the first experiment described here, the isolation efficiencies during linked MS n using the FNF technique were studied. This is important for those ions that are kept stable intentionally in the trap, while precursor or product ions are simultaneously activated by CID. Figure 2 shows ion isolation efficiencies for Enoxacin ([MH]+ at m/z 321) in the MS(2→3) step. A 6 u wide mass window was chosen to isolate the [MH − 18]+ ion of Enoxacin at m/z 303 (isolation band m/z 300–306). The FNF tickle voltage was turned off during MS(2→3); that is, only the FNF isolation step was studied. As can be seen from the figure, the isolation efficiencies during MS(2→3) were high (≈90–100%) while simultaneously a significant decrease of unwanted ions was observed (>90%). Interestingly, the ion at m/z 257 in the MS3 spectrum corresponds to an in situ HF loss from m/z 277 induced by the FNF isolation voltage. Obviously, a slightly larger FNF amplitude for the mass range m/z < 300 than for m/z > 306 would have removed this ion efficiently. Unfortunately, the FNF software version used here did not allow us to make that adjustment (see below). Isolation efficiencies in MS n using FNF. . In the next experiment, multiple CID was achieved by activating Enoxacin in the ion-trap via simultaneous application of several reverse-notch excitation bands. Linked MS n spectra were generated by simultaneously applying the FNF tickle frequencies for the precursor ion (m/z 321) and two of the intermediate product ions (m/z 277, 257; corresponding to [MH − CO2]+ and [MH − CO2-HF]+). At the same time, selected product ions from the MS2 step remained in the ion-trap (e.g. [MH − H2O]+ at m/z 303). As a result, a structure-informative CID spectrum was generated in one fast scan-cycle (Fig. 3). The CID efficiencies were high; values between 50–70% were usually obtained in the linked MS3 sequences. In the spectrum, intense product ions corresponding to characteristic losses from the carboxyl group and from the C-6, C-7 and N-1 portions are observed (cf. Ref. 5 for structure assignments). In contrast, in the single MS/MS spectrum obtained on the ion-trap or a triple-quadrupole instrument, m/z 303 and 277 were observed almost exclusively, corresponding to unspecific losses from the carboxyl group.5 Linked MS n spectrum of Enoxacin ([MH]+, m/z 321). . In order to apply the developed linked MS n technique to real-life samples, the quinolones were investigated in urine samples. The extraction of the analytes from urine was achieved with a restricted access material (RAM) using an on-line column switching setup. The porous RAM particles have a defined exclusion barrier and a non-adsorptive outer particle surface towards macromolecular matrix components (e.g. proteins). Small molecules have free access to the binding sites and thus can be extracted and enriched prior to their analytical separation. RAM columns allow the direct and multiple injection of urine and other complex samples. (The sample extraction procedure is described in detail elsewhere.6) The extracted quinolones were then separated on a short RP-18 column. Identification of the analytes was achieved by using linked MS n in one rapid scan-cycle (200 ms) as described above. Figure 4 shows an example of such an identification and confirmation procedure in a urine sample. Linked LC/MS n chromatogram for Enoxacin (ca. 1 ppm in urine) after on-line RAM enrichment of 100 µL of a urine sample. The FNF tickle frequencies for the precursor ion (m/z 321) and one of the intermediate product ions (m/z 277) were applied simultaneously; the resultant in situ MS3 transition (321 ⇒ 277 ⇒ 257) was monitored for identification in one scan-cycle. In conclusion, the FNF routines developed readily simplified MS n experiments by combining several fragmentation, isolation and further fragmentation steps in a single FNF sequence. The highly specific linked fragmentation reactions, which are normally only available in consecutive MS n experiments, could be combined in one fast scan-cycle by simultaneously applying several reverse-notch excitation bands. This technique makes combinations of linked MS n with fast chromatography separations readily possible. The linked sequences were successfully applied to the identification and confirmation of drug residues in urine samples in this study. To further extend the use of FNF, it is highly desirable that the individual frequency components can be individually adjusted so that CID spectra with product ion abundances of equal or similar intensities are obtained. Such CID spectra would be very useful in regulatory applications, as guidelines for the use of mass spectrometry as a confirmatory method usually recommend monitoring at least three structurally diagnostic ions per analyte.4, 5 In addition to the application shown here, a potential further application of linked MS n using FNF could be the removal of interfering MS/MS masses of isobaric precursor signals originating from matrix components in regulatory applications. FNF could be used to selectively remove the unwanted products ions from the MS/MS traces. Dietrich A. Volmer*, Stefan Niedziella*, * Merck Analytical Research, Frankfurter Str. 250, D-64271 Darmstadt, Germany.
No takes yet. Share an insight, caveat, or question.
Volmer et al. (2000) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: