A lab-on-fiber (LOF) optofluidic platform that provides physiologically relevant microenvironment was developed by integrating a long period grating (LPG) coupled with high order cladding mode to achieve high index sensitivity and a liquid-tight capillary tube assembly as a microfluidic chamber for LPG to mimic physiologically relevant microenvironment. We demonstrate the utility of LOF for in situ monitoring the construction of the [chitosan (CHI)/poly (acrylic acid) (PAA)/gentamicin sulfate (GS)/PAA]n multilayers at monolayer resolution as well as evaluating the rate of GS release at a flow rate of 0.127 mL/min at 37 °C in real time. We reveal that GS is released at a faster rate under the dynamic flow condition than in a static medium. Our findings underscore the importance of conducting drug release studies in physiologically relevant conditions.
No takes yet. Share an insight, caveat, or question.
Tian et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: