Jaundice is a common neonatal syndrome. Neonatal hyperbilirubinemia is a complex biologic phenomenon resulting from increased production and limited elimination of bilirubin during the transitional time after birth. Bilirubin production is 2 to 3 times higher in normal term newborns compared with adults, and is greatly exacerbated by hemolysis from any cause, the breakdown of extravascular blood, the shorter red cell life span associated with prematurity, maternal diabetes, cholestasis, unknown factors associated with ethnicity, and many other conditions. Thus, increased bilirubin production is an important contributing cause of all kinds of neonatal jaundice.The ability to predict the degree of jaundice based on the rate of bilirubin production is limited because bilirubin elimination varies greatly from individual to individual in the transitional time after birth. Nonetheless, identifying high producers of bilirubin is important for the diagnosis of hemolysis or the recognition of other risk factors associated with increased bilirubin production. Such risk factors have been identified in the new AAP practice parameter on the management of hyperbilirubinemia in the healthy term neonate1 as important exclusions for a neonate enrolled into the recommended management algorithm. Moreover, information about bilirubin production provides an accurate means of targeting individuals or populations for treatment with heme oxygenase (HO) inhibitors or for assessing the treatment efficacy of a particular HO inhibitor in an individual patient, monitoring directly the mechanism of action of the drug and evaluating dose response.Because carbon monoxide (CO) and biliverdin are produced in equimolar amounts and biliverdin is quantitatively reduced to bilirubin, the measurement of CO in breath or blood can be used as an index of heme degradation and bilirubin production in vivo. The validity of this approach has been well-established.2 The association of increased CO production with kernicterus and death related to hyperbilirubinemia in jaundiced Nigerian infants has also been reported.3 Although nothing has been published that explains convincingly why hemolysis would confer greater risk for injury associated with hyperbilirubinemia, the association of increased bilirubin production, (as indexed by increased CO production), and kernicterus in the Nigerian cohort3 suggests a possible explanation without invoking some unknown, mysterious factor consequent to hemolysis per se. In fact, a serum bilirubin level is a poor surrogate for total bilirubin production. The reason is that the amount of bilirubin that can be retained in circulation depends greatly on the amount of albumin in circulation and the affinity of albumin for bilirubin. If bilirubin production is high and the maximum bilirubin binding capacity in circulation is approached, bilirubin moves in increasing amounts outside the circulation into a variety of tissues, including the brain. Thus, the serum bilirubin concentration, particularly at elevated levels, frequently does not reflect accurately the total body bilirubin load. Another way in which this dynamic circumstance is reflected is in the rate of rise of the serum bilirubin concentration. A more rapid rise in the serum bilirubin concentration often results from increased bilirubin production. However, the rate of rise of the serum bilirubin concentration is probably not the critical factor; it is the fact that a large load of bilirubin is being presented to the circulation over a short interval of time and will rapidly exceed the capacity for binding in circulation. Thus, increased bilirubin production might serve as a index of risk for injury or death relative to the serum bilirubin level. The risk for injury or death would be greatest with the highest bilirubin production and the highest serum bilirubin level. Delay in or impairment of bilirubin elimination would only amplify the factor of increased bilirubin production. This interpretation is consistent with empirical observations and is consistent with the hypothesis relating risk of injury associated with hyperbilirubinemia to free bilirubin levels. Moreover, a relationship between increased bilirubin production, increased free bilirubin levels, and total body bilirubin load would thus be anticipated in circumstances associated with the highest risk for injury in association with hyperbilirubinemia.Recent studies conducted for the National Institute of Child Health and Human Development (NICHD) Neonatal Research Network demonstrate the feasibility of estimating bilirubin production as measured by CO in breath.45 Since those studies were completed, there have been several modifications of the earlier prototype breath collection and analysis system to improve recovery, accuracy, and reliability. First, a continuously biased hydrogen compensated detector has been substituted for the original detector. This has reduced the interpatient variability of the results, because compensation can now be set to result in a hydrogen-induced error of less than .1 ppm CO for 100 ppm hydrogen. The hydrogen sensitivity of the original CO detector limited its application to a narrow 2- to 8-hour window of sampling in the NICHD Neonatal Research Network studies. The present analyzer also automatically resets the CO detector zero every 30 minutes, reducing detector drift error. It uses one room air reading as a measure of inhaled CO for repeat measurements of end-tidal breath on the same patient for a period up to 10 minutes. This reduces the intrapatient variability of the readings. The initial plumbing path was found to amplify the effect of pressure/vacuum sensitivity of the detector, and cause early detector failure and variability of measurement. In addition, the plumbing path allowed for contamination of the flow measurement orifice. The initial path has been changed in such a way that the orifice and detector are protected by a prefilter, and the detector only operates at atmospheric pressure. This greatly enhances the repeatability of readings. The accuracy of the reading is a direct function of the precision with which calibration gases can be obtained and read. The software has been modified to use CO calibration gases of twice the concentration (20 μL/L) effectively reducing the calibration accuracy by one-half. The above noted changes allow the detector to quickly reach equilibrium. The software allows a reading to be computed when only the last 15 seconds of a respiratory sample are stable. The addition of a balloon or bag analysis mode allows repeat analyses of the same breath sample for a cooperative patient. The measurements obtained in this manner demonstrate the repeatability of the instrument's measuring technique.Estimates of endogenous CO production can be obtained from measurements of CO in end-tidal breath corrected for inhaled CO (ETCOc) and may be used for the diagnosis of hemolytic disease. We evaluated the modified, portable, noninvasive breath sampler analyzer instrument (Baby's Breath Carbon Monoxide Analyzer, Natus Medical, Inc), developed specifically for difficult to sample neonates.6 The instrument can also be used on adults and with samples of breath collected into bags. Bench tests with CO in air mixtures demonstrated that the instrument's CO measuring function was linear (up to 25 μL CO/L), accurate, and precise when compared with the gas chromatographic (GC) reference method. In vivo tests with nonsmoking and smoking adults (n = 30) showed excellent correlation between the mean of triplicate ETCOc measurements by Baby's Breath compared with GC. The instrument was not sensitive to hydrogen. Simultaneous measurements of carbon dioxide indicated a breath sampling efficiency of 96%. Linear regression analysis of ETCOc measurements and blood carboxyhemoglobin fractions corrected for inhaled CO determined by GC showed a good correlation [carboxyhemoglobin corrected for inhaled CO total hemoglobin = .25 ETCOc–.01 μL CO/L, r2 = .97]. Measurements in healthy and hemolytic term newborns indicated that an ETCOc value of ≥3 ppm correlated with known hemolysis. The imprecision for normal and high CO producers determined from the mean coefficient of variation of triplicate ETCOc measurements was 11%. We conclude that the tested instrument is accurate, and precise enough for the detection of hemolysis in neonates and smoking habit in adults.Studies have also been conducted on the variability of interlaboratory bilirubin measurements by the NICHD Neonatal Research Network.7 Accurate measurement of serum total bilirubin is important in clinical practice. In the course of the Neonatal NICU Network studies, we measured serum total bilirubin concentrations at 14 different laboratories using the local automated analytical systems. Quality control was monitored through monthly analysis of commercially available bovine serum albumin-based reference specimens containing 38 (2.2), 169 (9.9), and 253 μmol bilirubin/L (14.8 mg/dL). The measured mean ± standard deviation (n, range) of these reference specimens were: 39 ± 7 μmol/L (n = 90, 29–55) [2.3 ± 0.4 mg/dL (n = 90, 1.7–3.2)]; 176 ± 29 μmol/L (n = 89, 137–217) [10.3 ± 1.7 mg/dL (n = 89, 8.0–12.7)]; and 260 ± 43 μmol/L (n = 103, 207–316) [15.2 ± 2.5 mg/dL (n = 103, 12.1–18.5)]. Measurements, compared with target values, were consistently lower at four, higher at six, and equal (within 100 ± 4%) at four laboratories for each of the three levels. The measured values for each level remained fairly constant for the duration of the study indicating consistent internal quality control at each laboratory. There was no correlation between the methodology used and the results obtained. We conclude that bilirubin measurements differed significantly from established reference values at most of the participating laboratories. Under- and overestimation of total bilirubin levels could lead to omission of needed therapy or erroneous clinical information in some newborn infants. These studies demonstrate the current imprecision with respect to this common laboratory measurement. Direct estimates of bilirubin production are more precise, and would be a better way of assessing the efficacy of HO inhibitor treatment and drug dose response. conclusion: 1) the measurement of bilirubin production as estimated by breath may be helpful in the diagnosis of risk factors such as hemolysis in newborn infants; 2) the targeting of high-risk, high producers for treatment may be useful if treatments invoke any risk; and 3) the monitoring of HO inhibitor treatment with breath CO measurements would allow better assessment of dose response and tracking of efficacy in individual patients.This work was supported in part by a grant from the National Institutes of Health (HD14426), the Providence Foundation, and the Mary L. Johnson Research Fund.
No takes yet. Share an insight, caveat, or question.
Stevenson et al. (1997) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: