Answers are grounded in this paper and cite their sources.
The authors studied the effect of the position of the averaging volume on the averaged specific-absorption-rate values at the typical European cellular telephone frequencies around 900 and 1800 MHz. The Council of the European Union recommends a 10-g contiguous volume, as the averaging volume. A simple cubic tissue can be used provided that the calculated dosimetric quantities have conservative values relative to the exposure guidelines of the Council of the European Union. Large differences can occur depending on the averaging procedure. The situation is definitely most critical at 1800 MHz.
No takes yet. Share an insight, caveat, or question.
Martens et al. (2000) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: