We draw together the results of two different types of experiments on the Au(110) surface and show they are mutually consistent. Glancing incidence x-ray diffraction showed surface Bragg peaks displaced along [100], indicating that the surface has an average spacing different from the bulk in that direction. The local structure was found to be a 2×{}1 "missing-row" morphology. Rutherford-backscattering (He⁺) measurements of the Au(110)-〈110〉 surface peak were significantly larger than expected for a simple missing-row model. Lateral displacements in the second layer of the solid are necessary for agreement with both sets of measurements, and the two derived magnitudes (0.12 {}) are the same. Evidence for a large vertical displacement of the top layer is also obtained by both techniques. The inclusion of a specific domain structure along [100] brings this model into agreement with all experimental evidence.
No takes yet. Share an insight, caveat, or question.
Robinson et al. (1984) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: