The temperature dependence on the breakdown voltages of InP/InGaAs avalanche photodiode was investigated in the range between -20°C and 100°C. It was found that the normalized first derivative of the breakdown voltage with respect to temperature decreased linearly as the breakdown voltage increased. Furthermore, the extrapolations of all the tested samples converge at the temperature independent limiting value of breakdown voltage. According to our analysis on these phenomena, we propose an empirical formula of temperature dependent breakdown voltages.
No takes yet. Share an insight, caveat, or question.
Hyun et al. (1996) studied this question.