Does ultraviolet radiation devitalize enteric viruses in estuarine water?
Does ultraviolet radiation devitalize enteric viruses in estuarine water?
Ultraviolet radiation is highly effective in devitalizing enteric viruses in estuarine water, with viral half-lives ranging from 2.7 to 4.0 seconds.
UV may aid estuarine water disinfection strategies; leaves open real-world efficacy and safety given Level 5 evidence.
The effect of ultraviolet (UV) radiation on the devitalization of eight selected enteric viruses suspended in estuarine water was determined. The surviving fractions of each virus were calculated and then plotted against the UV exposure time for purposes of comparison. Analytical assessment of the survival data for each virus consisted of least squares regression analysis for determination of intercepts and slope functions. All data were examined for statistical significance. When the slope function of each virus was compared against the slope function of poliovirus type 1, the analytical findings indicated that poliovirus types 2 and 3, echovirus types 1 and 11, and coxsackievirus A-9 exhibited similar devitalization characteristics in that no statistically significant difference was found (P > 0.05). Conversely, the devitalization characteristics of coxsackievirus B-1 and reovirus type 1 were dissimilar from those of poliovirus type 1 in that a statistically significant difference was found between the slope functions (P < 0.05). This observed difference in devitalization of coxsackievirus B-1 and reovirus type 1 was attributed primarily to the frequency distribution of single and aggregate virions, the geometric configuration, the size of the aggregates, and the severity of aggregation. The devitalization curve of coxsackievirus B-1 was characteristic of a retardant die-away curve. The devitalization curve of reovirus type 1 was characteristic of a multihittype curve. The calculated devitalization half-life values for poliovirus types 1, 2, and 3; echovirus types 1 and 11; coxsackievirus types A-9 and B-1; and reovirus type 1 were 2.8, 3.1, 2.7, 2.8, 3.2, 3.1, 4.0, 4.0 sec, respectively. These basic data should facilitate an operative extrapolation of the findings to the applied situation. It was concluded that UV can be highly effective and provide a reliable safety factor in treating estuarine water.
No takes yet. Share an insight, caveat, or question.
Hill et al. (1970) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: