Within-subject agreement study reveals 60-minute 18F-flutemetamol PET reliably bridges to standard 90-minute Centiloid measures, indicating shorter scan wait times are clinically feasible.
This study evaluated whether delayed static 18 F-flutemetamol PET acquired at 60 min post-injection on digital SiPM PET/CT can be quantitatively bridged to the conventional 90-min Centiloid (CL) scale while preserving visual interpretability. Methods: In the derivation cohort, 63 participants underwent paired 60- and 90-min static 18 F-flutemetamol PET acquisitions on digital SiPM PET/CT systems. Three experienced readers independently performed visual assessment (VA) at each time point. Raw quantitative agreement between acquisition windows was first evaluated using SUVR and direct VIZCalc-derived CL values. A study-derived SUVR₆₀-to-CL₉₀ conversion equation was then developed and evaluated using Bland–Altman analysis, Lin’s concordance correlation coefficient (CCC), and leave-one-out cross-validation. The same equation was additionally applied without refitting to an independent internal validation cohort of 34 paired examinations. Results: The majority VA was concordant between 60 and 90 min in 62/63 examinations (98.4%; Cohen’s κ = 0.968). Raw SUVR₆₀ and SUVR₉₀, as well as raw CL₆₀ and raw CL₉₀, were highly correlated but showed systematic time-window differences and limited direct numerical agreement. After calibration, CL₉₀(est.60) showed excellent agreement with CL₉₀ in the derivation cohort (CCC = 0.997; bias − 0.01 CL; 95% limits of agreement, − 5.94 to 5.93 CL). In the independent internal validation cohort, CL₉₀(est.60) retained strong agreement with CL₉₀ (CCC = 0.997; bias − 1.78 CL; 95% limits of agreement, − 8.00 to 4.43 CL), with 30/34 examinations (88.2%) within ± 5 CL. CL-based classification showed high agreement with majority VA across prespecified thresholds. Voxel-wise analysis demonstrated time-window-dependent differences predominantly characterized by higher white matter signal at 90 min. Raw 60- and 90-min quantitative values for 18 F-flutemetamol PET are highly correlated but should not be regarded as directly numerically interchangeable. However, 60-min SUVR can be bridged to the conventional 90-min CL scale using a protocol-specific conversion equation, with preserved visual agreement and strong internal validation performance. These findings support the feasibility of a shortened delayed imaging protocol on digital SiPM PET/CT, provided that quantitative interpretation uses appropriate calibration and borderline cases are interpreted with caution.
No takes yet. Share an insight, caveat, or question.
Sohara et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: