Key result
Geometric height, annular diameter, and sinotubular junction diameter strongly correlate with normal aortic valve effective height.
Why the study?
The study was conducted to analyze the relationship between effective height and other morphological parameters of the aortic valve complex when the aortic valve is closed.
Cross-Sectional (n=105)
Effect estimate: R2=0.739
p-value: p=<0.001
Effective height of the aortic valve is strongly and independently associated with geometric height, aortic annular diameter, and sinotubular junction diameter in morphologically normal tricuspid aortic valves.
Supports geometric modeling of effective height in normal valves; leaves open translation to diseased valves or surgical planning.
Objectives To analyse the relationship between effective height and other morphological parameters of the aortic valve complex when the aortic valve is closed. Methods We retrospectively analysed 105 patients (mean age 70.7±10.1 years) with morphologically normal aortic valves, roots, or ascending aortas who had undergone electrocardiography-gated cardiac computed tomography as a screening test of the coronary artery, from August 2014 to December 2018. Parameters of the aortic valve complex configuration (effective height, geometric height, aortic annular diameter, sinus of Valsalva diameter, sinotubular junction diameter, commissure height, and Valsalva height) in diastole were measured using Ziostation2 software. Pearson’s correlation was used to evaluate the associations between the effective height and other parameters. Multiple regression analysis was performed to evaluate the variables independently associated with effective height. Results Significant associations were observed between the effective height and geometric height, sinus of Valsalva diameter, sinotubular junction diameter, commissure height, and Valsalva height (all p < 0.001) but not between effective height and aortic annular diameter (p = 0.227). Multivariable analysis showed that geometric height, aortic annular diameter, and sinotubular junction diameter were independently associated with effective height (all p < 0.001; overall model fit: R2=0.739). Conclusions Our findings demonstrate that effective height is strongly associated with geometric height, which remained independently associated after adjustment, along with aortic annular and sinotubular junction diameters. These results provide quantitative in vivo evidence regarding the anatomical determinants of effective height in morphologically normal tricuspid aortic valves and may serve as anatomical reference data for future research on individualised approaches to aortic valve repair.
No takes yet. Share an insight, caveat, or question.
Ishida et al. (2026) conducted a cross-sectional in Morphologically normal aortic valves (n=105). Anatomical parameters of the aortic valve complex was evaluated on Effective height of the aortic valve (R2=0.739, p=<0.001). Geometric height, aortic annular diameter, and sinotubular junction diameter were independently associated with effective height in morphologically normal tricuspid aortic valves (all p < 0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: