Why the study?
It was unknown whether drop-set and crescent pyramid resistance training systems produce different microvascular oxygenation status and muscle activation compared with traditional resistance training.
Do drop-set and crescent pyramid resistance training systems produce different microvascular oxygenation status and muscle activation compared to traditional resistance training in volunteers?
Do drop-set and crescent pyramid resistance training systems produce different microvascular oxygenation status and muscle activation compared to traditional resistance training in volunteers?
Drop-set resistance training produces lower microvascular oxygenation levels compared with traditional and crescent pyramid training, though muscle activation levels remain similar across protocols.
Drop-set may be selected when greater acute deoxygenation is desired; extends RCT evidence comparing microvascular responses across resistance protocols.
International Journal of Exercise Science 13(2): 1549-1562, 2020. Metabolic stress is a primary mechanism of muscle hypertrophy and is associated with microvascular oxygenation and muscle activation. Considering that drop-set (DS) and crescent pyramid (CP) resistance training systems are recommended to modulate these mechanisms related to muscle hypertrophy, we aimed to investigate if these resistance training systems produce a different microvascular oxygenation status and muscle activation from those observed in traditional resistance training (TRAD). Twelve volunteers had their legs randomized in an intra-subject cross-over design in TRAD (3 sets of 10 repetitions at 75% 1-RM), DS (3 sets of ~50-75% 1-RM) and CP (3 sets of 6-10 repetitions at 75-85% 1-RM). Vastus medialis microvascular oxygenation and muscle activation were respectively assessed by non- invasive near-infrared spectroscopy and surface electromyography techniques during the resistance training sessions in the leg-extension exercise. Total hemoglobin area under the curve (AUC) (TRAD: -1653.5 ± 2866.5; DS: -3069.2 ± 3429.4; CP: -1196.6 ± 2675.3) and tissue oxygen saturation (TRAD: 19283.1 ± 6698.0; DS: 23995.5 ± 15604.9; CP: 16109.1 ± 8553.1) increased without differences between protocols (p>0.05). Greater decreases in oxygenated hemoglobin AUC and hemoglobin differentiated AUC were respectively found for DS (-4036.8 ± 2698.1; -5004.4 ± 2722.9) compared with TRAD (-1951.8 ± 1720.0; -2250.3 ± 1305.7) and CP (-1814.4 ± 2634.3; 2432.2 ± 2891.4) (p<0.03). Higher increases of hemoglobin deoxygenated AUC were found for DS (1426.7 ± 1320.7) compared with TRAD (316.0 ± 1164.9) only (p=0.04). No differences were demonstrated in electromyographic amplitudes between TRAD (69.0 ± 34.4), DS (61.3 ± 26.7) and CP (60.9 ± 38.8) (p>0.05). Despite DS produced lower microvascular oxygenation levels compared with TRAD and CP, all protocols produced similar muscle activation levels.
No takes yet. Share an insight, caveat, or question.
Vitor Angleri (2020) studied this question.