We present the design, fabrication, and testing of a push-pull differential resonant accelerometer with double-ended-tuning-fork (DETF) as the inertial force sensor. The accelerometer is fabricated with the silicon-on-insulator microelectromechanical systems (MEMS) technology that bridges surface micromachining and bulk micromachining by integrating the 50-/spl mu/m-thick high-aspect ratio MEMS structure with the standard circuit foundry process. Two DETF resonators serve as the force sensor measuring the acceleration through a frequency shift caused by the inertial force acting as axial loading. Two-stage microleverage mechanisms with an amplification factor of 80 are designed for force amplification to increase the overall sensitivity to 160 Hz/g, which is confirmed by the experimental value of 158 Hz/g. Trans-resistance amplifiers are designed and integrated on the same chip for output signal amplification and processing. The 50-/spl mu/m thickness of the high-aspect ratio MEMS structure has no effect on the amplification factor of the mechanism but contributes to a greater capacitance force; therefore, the resonator can be actuated by a much lower ac voltage comparing to the 2-/spl mu/m-thick DETF resonators. The testing results agree with the designed sensitivity for static acceleration.