Authors
This paper presents test results on problems and solutions of motor shaft voltages and bearing currents in medium-voltage pulsewidth modulated (PWM) drive systems. Tests show that multilevel medium-voltage PWM voltage-source inverter drives can cause motor bearing currents, similar to a low-voltage PWM drives, even with one motor bearing insulated. Common-mode voltages generated as a result of PWM switching are observed on motor windings and capacitively coupled to the motor shaft, leading to bearing currents. Potential solutions, including altering common-mode circuitry, changing the grounding scheme, providing common-mode filtering, and grounding the motor shaft, are investigated. Test results on their effectiveness are presented.
No takes yet. Share an insight, caveat, or question.
Fei Wang (2000) studied this question.