Answers are grounded in this paper and cite their sources.
The attenuation of ultrasonic waves has been investigated in single-crystal α^'-phase palladium hydride (PdH0.64) over the temperature range of 77-300 K. The longitudinal and two independent transverse waves were propagated along the [110] crystal axis. These correspond to the elastic constants CL=1/2(C₁₁+C₁₂+2C₄₄), C^'=1/2(C₁₁-C₁₂), and C₄₄. Attenuation peaks were observed for all three modes. At 10 MHz the maxima occurred at approximately 190 K for CL and C^', and 180 K for C₄₄. The peaks are attributed to a stress-induced ordering of hydrogen pairs and complexes, and vacancy pairs and complexes, on the hydrogen sublattice. The relative magnitudes of the peaks are well accounted for in terms of hydrogen-hydrogen, hydrogen-vacancy, and vacancy-vacancy interactions at nearest- and next-nearest-neighbor positions. A simple nearest-neighbor interaction is shown to be inadequate to explain the results. The gradients of the hydrogen-vacancy interaction energies at nearest- and next-nearest-neighbor sites are deduced, with the main uncertainty having to do with the selection of an anelastic critical temperature in the theoretical expression. Using 50 K for the critical temperature we find 5.4×{}10^-11 and 3.8×{}10^-11 N for the absolute value of the gradients at nearest- and next-nearest-neighbor sites, respectively. The three measured attenuation peaks were found to satisfy a Cauchy-type relationship. Such a relationship suggests a central-force description of the interactions among hydrogen atoms and vacancies. The existence of a hydrostatic mode of relaxation is shown for the first time for this system. The relaxation rate for this mode is approximately the same as that for CL and C^', while the C₄₄ mode relaxes approximately twice as fast. Plots of the attenuation times the temperature versus inverse temperature are asymmetric. Such asymmetry was previously observed in internal-friction measurements and attributed to the existence of an anelastic critical temperature. Our data, taken at higher frequencies and thus higher temperatures, can be fitted using an anelastic critical temperature, but the value is considerably higher than that deduced from the internal-friction experiments. The difference suggests that the asymmetry is not due to a critical temperature, but has some other origin.
No takes yet. Share an insight, caveat, or question.
Leisure et al. (1983) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: