Answers are grounded in this paper and cite their sources.
Background: This study assessed the safety, performance and user satisfaction of a new version of the ABLE Exoskeleton for gait training in people with spinal cord injury (SCI). This new hip-knee powered version of the exoskeleton ABLEhipknee has been developed taking into account the results of clinical trials with the previous knee powered version ABLEknee and feedback from clinicians and patients. Methods: In this quasi-experimental study, a 10-session training program with the ABLEhipknee version was conducted on five participants with chronic, thoracic motor-complete SCI. Safety (device-related adverse events) and performance outcomes (level of assistance, donning/doffing time, therapy metrics) were recorded at every session. Standard clinical tests including 6MWT, 10MWT and TUG were carried out in the last session. The results from the present study were compared against the results obtained by a similar subset of participants from previous clinical trials with the ABLEknee version. Results: The participants achieved a significantly better performance (higher walking time, number of steps, and distance walked, p<0.001) and experienced fewer device-related adverse events than participants from previous clinical trials where the ABLEknee was used. Participants of the present study also required lower levels of assistance to complete the therapy activities and achieved a significantly higher walking distance during the 6MWT compared to the previous clinical trials. The time to don/doff the ABLEhipknee took on average 3 minutes more than the ABLEknee with comparable levels of assistance. Regarding user satisfaction, the ABLEhipknee presented on average higher scores than the ABLEknee. Conclusions: This study shows that, after the design changes performed on the ABLE Exoskeleton, the device continues to be safe for gait rehabilitation in people with SCI in a hospital setting. Moreover, the ABLEhipknee proved to be superior in terms of performance, with higher satisfaction scores as rated by participants and therapists. Overall, the results highlight the importance of co-creation to develop meaningful rehabilitation technology, engaging with people living with SCI and therapists as part of the team, to integrate their feedback into the design and better address their needs. Trial registration: NCT05590065
No takes yet. Share an insight, caveat, or question.
Porras-Martínez et al. (2023) studied this question.