Key result
Ultrasound monitoring of tissue-engineered heart valves in bioreactors provided three-dimensional geometric assessment and real-time flow evaluation compared to standard optical imaging.
Why the study?
Does ultrasound monitoring provide better functional and geometric evaluation of tissue-engineered heart valves in vitro compared to optical imaging?
Does ultrasound monitoring provide better functional and geometric evaluation of tissue-engineered heart valves in vitro compared to optical imaging?
Ultrasound provides a noninvasive, real-time method for comprehensive 3D geometric and functional assessment of tissue-engineered heart valves during in vitro maturation.
Ultrasound may aid bioreactor-based valve development; leaves open clinical translation of tissue-engineered valves.
Tissue-engineered heart valves are developed in bioreactors where biochemical and mechanical stimuli are provided for extracellular matrix formation. During this phase, the monitoring possibilities are limited by the need to maintain the sterility and integrity of the valve. Therefore, noninvasive and nondestructive techniques are required. As such, optical imaging is commonly used to verify valve's functionality in vitro. It provides important information (i.e., leaflet symmetry, geometric orifice area, and closing and opening times), which is, however, usually limited to a singular view along the central axis from the outflow side. In this study, we propose ultrasound as a monitoring method that, in contrast to established optical imaging, can assess the valve from different planes, scanning the whole three-dimensional geometry. We show the potential benefits associated with the application of ultrasound to bioreactors, in advancing heart valve tissue engineering from design to fabrication and in vitro maturation. Specifically, we demonstrate that additional information, otherwise unavailable, can be gained to evaluate the valve's functionality (e.g., coaptation length, and effective cusp height and shape). Furthermore, we show that Doppler techniques provide qualitative visualization and quantitative evaluation of the flow through the valve, in real time and throughout the whole in vitro fabrication phase.
No takes yet. Share an insight, caveat, or question.
Hurtado-Aguilar et al. (2016) studied Tissue-engineered heart valves. Ultrasound monitoring vs. Optical imaging was evaluated on Valve functionality (coaptation length, effective cusp height and shape, flow visualization). Ultrasound monitoring of tissue-engineered heart valves in bioreactors provided three-dimensional geometric assessment and real-time flow evaluation compared to standard optical imaging.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: