Key result
The proposed camera-based heart rate estimation method achieved a mean absolute error of 3.39 BPM during rest and 4.34 BPM during visible movements compared to ground-truth ECG in hospitalized newborns.
Why the study?
RGB camera-based non-contact heart rate measurement techniques suffered poor robustness in infants due to frequent body movement.
Does RGB camera-based heart rate estimation accurately measure heart rate compared to ECG in hospitalized newborns in the presence of motion artifacts?
Observational (n=9)
No
Does RGB camera-based heart rate estimation accurately measure heart rate compared to ECG in hospitalized newborns in the presence of motion artifacts?
Answers are grounded in this paper and cite their sources.
An RGB camera-based non-contact heart rate measurement system using Eulerian video magnification and majority voting can accurately estimate neonatal heart rate even in the presence of visible movements.
BACKGROUND: Heart rate (HR) is an important vital sign for evaluating the physiological condition of a newborn infant. Recently, for measuring HR, novel RGB camera-based non-contact techniques have demonstrated their specific superiority compared with other techniques, such as dopplers and thermal cameras. However, they still suffered poor robustness in infants' HR measurements due to frequent body movement. METHODS: This paper introduces a framework to improve the robustness of infants' HR measurements by solving motion artifact problems. Our solution is based on the following steps: morphology-based filtering, region-of-interest (ROI) dividing, Eulerian video magnification and majority voting. In particular, ROI dividing improves ROI information utilization. The majority voting scheme improves the statistical robustness by choosing the HR with the highest probability. Additionally, we determined the dividing parameter that leads to the most accurate HR measurements. In order to examine the performance of the proposed method, we collected 4 hours of videos and recorded the corresponding electrocardiogram (ECG) of 9 hospitalized neonates under two different conditions-rest still and visible movements. RESULTS: Experimental results indicate a promising performance: the mean absolute error during rest still and visible movements are 3.39 beats per minute (BPM) and 4.34 BPM, respectively, which improves at least 2.00 and 1.88 BPM compared with previous works. The Bland-Altman plots also show the remarkable consistency of our results and the HR derived from the ground-truth ECG. CONCLUSIONS: To the best of our knowledge, this is the first study aimed at improving the robustness of neonatal HR measurement under motion artifacts using an RGB camera. The preliminary results have shown the promising prospects of the proposed method, which hopefully reduce neonatal mortality in hospitals.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2021) conducted an observational in Hospitalized newborns (n=9). Camera-based heart rate estimation (Eulerian video magnification and majority voting) vs. Electrocardiogram (ECG) was evaluated on Mean absolute error (MAE) of heart rate measurement compared to ECG (MAE 3.39 BPM (rest) and 4.34 BPM (movement)). The proposed camera-based heart rate estimation method achieved a mean absolute error of 3.39 BPM during rest and 4.34 BPM during visible movements compared to ground-truth ECG in hospitalized newborns.