Key result
A 6-week trial of warfarin anticoagulation in an 83-year-old man with suspected bioprosthetic aortic valve thrombosis reduced the mean transvalvular gradient from 48 mmHg to 14 mmHg.
Why the study?
Does warfarin anticoagulation improve elevated transvalvular gradients in patients with suspected bioprosthetic aortic valve thrombosis?
Case Report (n=1)
Does warfarin anticoagulation improve elevated transvalvular gradients in patients with suspected bioprosthetic aortic valve thrombosis?
A trial of warfarin anticoagulation can rapidly reverse longstanding elevated transvalvular gradients caused by bioprosthetic aortic valve thrombosis, even years after valve implantation.
May warrant advanced imaging for symptomatic bioprosthetic gradients; leaves open standardized criteria for intervention timing.
An 83-year-old gentleman with a history of 23-mm Hancock-II-bioprosthetic aortic valve (BAV) replacement ten-years prior presented with symptoms of dyspnea and lower extremity edema. During the preceding seven-years, he had been noted to have asymptomatic increased mean transvalvular gradients (MG; 36-50 mmHg) felt to be due to either early bioprosthetic degeneration, pannus formation, or patient-prosthesis mismatch. An echocardiogram at the time of symptom development demonstrated significant flow acceleration through the aortic valve, mild regurgitation, and severely increased MG (48 mmHg) with prolonged acceleration time (AT, 140 msec). A trial of warfarin anticoagulation resulted in dramatic improvement after only 6 weeks with laminar flow through the AV, near-total resolution of regurgitation, and a decrease in MG to 14 mmHg and AT to 114 msec. These findings strongly suggest that BAV thrombosis was the predominant mechanism responsible for the longstanding high MG. Our case highlights that BAV thrombosis should be considered in the differential of elevated gradients regardless of the age of prosthesis, and that a trial of warfarin anticoagulation may be beneficial even if elevated gradients have been present for a prolonged period. Valvular gradients are often abnormal long before a formal diagnosis; however, these may reverse quickly with anticoagulation therapy.
No takes yet. Share an insight, caveat, or question.
Radovanovic et al. (2022) conducted a case report in Bioprosthetic aortic valve thrombosis (n=1). Warfarin anticoagulation was evaluated on Mean transvalvular gradient and acceleration time. A 6-week trial of warfarin anticoagulation in an 83-year-old man with suspected bioprosthetic aortic valve thrombosis reduced the mean transvalvular gradient from 48 mmHg to 14 mmHg.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: