Key result
Measurement of the fetal right modified myocardial performance index using synchronized RV inflow and outflow images showed high reproducibility (ICCs >0.950) and no difference from the conventional method (p = .242).
Why the study?
To evaluate the reproducibility of fetal right modified myocardial performance index obtained by synchronizing right ventricular inflow and outflow images and its feasibility in twin-to-twin transfusion syndrome.
Does synchronization of right ventricular inflow and outflow images provide reproducible measurements of fetal right Mod-MPI compared to conventional methods?
Observational (n=110)
Does synchronization of right ventricular inflow and outflow images provide reproducible measurements of fetal right Mod-MPI compared to conventional methods?
Synchronizing right ventricular inflow and outflow images is a highly reproducible and reliable novel technique for evaluating fetal right cardiac function, including in twin-to-twin transfusion syndrome.
Synchronized RV imaging supports reproducible fetal right Mod-MPI assessment; leaves open prospective validation before clinical adoption.
OBJECTIVE: To evaluate the reproducibility of the fetal right modified myocardial performance index (Mod-MPI) obtained by synchronizing the inflow and outflow images of the right ventricle (RV) and to evaluate its feasibility through clinical application to twin-to-twin transfusion syndrome (TTTS). METHODS: We prospectively evaluated 77 normal fetuses. Two experienced operators individually measured the right Mod-MPI using two different methods: (1) separate recording of the RV inflow and outflow using pulsed-wave Doppler (conventional method) and (2) synchronization of RV inflow and outflow images using the MPI + ™ function based on the closure click of the pulmonary valve (new method). To evaluate the clinical utility of the new method, we measured the right Mod-MPI in 33 TTTS fetuses using the new method before and after the fetoscopic laser coagulation (FLC). RESULTS: There was no statistical difference in Mod-MPI values between the two methods (p = .242). For both operators, the intra- and interoperator reproducibility of Mod-MPI was high with both methods (ICCs >0.950). Among the components of Mod-MPI measured using the new method, ejection time showed the highest reproducibility, whereas isovolumetric relaxation time demonstrated the lowest reproducibility. In TTTS fetuses, the Mod-MPI significantly decreased after FLC in recipients, and there was no difference in MPI values before and after FLC in donors. CONCLUSION: Right Mod-MPI measurement after the synchronization of RV inflow and outflow images is a reliable technique for evaluating fetal right cardiac function. This novel method can also independently evaluate the systolic and diastolic functions of the right heart.
No takes yet. Share an insight, caveat, or question.
Kang et al. (2021) conducted an observational in Twin-to-twin transfusion syndrome (TTTS) (n=110). Synchronization of RV inflow and outflow images (new method) vs. Separate recording of RV inflow and outflow (conventional method) was evaluated on Right modified myocardial performance index (Mod-MPI) values (p=.242). Measurement of the fetal right modified myocardial performance index using synchronized RV inflow and outflow images showed high reproducibility (ICCs >0.950) and no difference from the conventional method (p = .242).