This paper describes a technique that combines radial MRI and phase contrast (PC) to map the velocities of hyperpolarized gases ((3)He) in respiratory airways. The method was evaluated on well known geometries (straight and U-shaped pipes) before it was applied in vivo. Dynamic 2D maps of the three velocity components were obtained from a 10-mm slice with an in-plane spatial resolution of 1.6 mm within 1 s. Integration of the in vitro through-plane velocity over the slice matched the input flow within a relative precision of 6.4%. As expected for the given Reynolds number, a parabolic velocity profile was obtained in the straight pipe. In the U-shaped pipe the three velocity components were measured and compared to a fluid-dynamics simulation so the precision was evaluated as fine as 0.025 m s(-1). The technique also demonstrated its ability to visualize vortices and localize characteristic points, such as the maximum velocity and vortex-center positions. Finally, in vivo feasibility was demonstrated in the human trachea during inhalation.