Why the study?
Data regarding jugular venous pulse response to exercise are limited due to complex or invasive assessment procedures, prompting this feasibility test of a non-invasive wearable plethysmography system during submaximal exercise.
Does a wearable cervical plethysmography system feasibly monitor jugular venous pulse changes during submaximal exercise in healthy subjects?
Does a wearable cervical plethysmography system feasibly monitor jugular venous pulse changes during submaximal exercise in healthy subjects?
A novel wearable cervical plethysmography system can feasibly monitor jugular venous pulse changes during submaximal exercise, providing non-invasive insights into cardiac filling.
Non-invasive JVP plethysmography appears feasible during submaximal exercise; leaves open diagnostic utility pending validation in patients.
The jugular venous pulse (JVP) is a one of the crucial parameters of efficient cardiovascular function. Nowadays, limited data are available regarding the response of JVP to exercise because of its complex and/or invasive assessment procedure. The aim of the present work is to test the feasibility of a non-invasive JVP plethysmography system to monitor different submaximal exercise condition. Twenty (20) healthy subjects (13M/7F mean age 25 ± 3, BMI 21 ± 2) underwent cervical strain-gauge plethysmography, acquired synchronously with the electrocardiogram, while they were carrying out different activities: stand supine, upright, and during the execution of aerobic exercise (2 km walking test) and leg-press machine exercise (submaximal 6 RM test). Peaks a and x of the JVP waveform were investigated since they reflect the volume of cardiac filling. To this aim, the Δax parameter was introduced, representing the amplitude differences between a and x peaks. Significant differences in the values of a, x, and Δax were found between static and exercise conditions (p < 0.0001, p < 0.0001, p < 0.0001), respectively. Particularly, the Δax value for the leg press was approximately three times higher than the supine, and during walking was even nine times higher. The exercise monitoring by means of the novel JVP plethysmography system is feasible during submaximal exercise, and it provides additional parameters on cardiac filling and cerebral venous drainage to the widely used heartbeat rate value.
No takes yet. Share an insight, caveat, or question.
Menegatti et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: