Comprehensive numerical simulations with the transmission-line laser model (TLLM) are used to compare the behavior of gain-coupled DFB lasers with index-coupled DFB lasers fabricated from identical materials. These simulations compare slope efficiency, threshold current, spectra, small-signal modulation bandwidth, maximum-intrinsic modulation bandwidth, large-signal transient response and chirp, relative-intensity-noise (RIN) spectra, and feedback sensitivity for coherence collapse. In most cases gain-coupled lasers with additional index coupling have better performance than index-coupled lasers for a given material. However, high-coupling factor index-coupled lasers do have lower threshold currents, lower RIN levels, and lower sensitivity to external feedback than gain-coupled lasers, although spatial hole burning in these devices can be disadvantageous.>